IC 7362A-RAD87 by MASIMO CORP. for Pulse Oximeter

IC ID: 7362A-RAD87 / 7362ARAD87

Model:  Rad-87

Company Number: 7362A
Company Name: MASIMO CORP.
Certification Number: 7362A-RAD87
Approval Date: 2007-10-29
Type of Radio Equipment: Spread Spectrum/Digital Device (2400-2483.5 MHz) WLAN
Equipment Type:Radio Equipment (RE)
Certified By: CKC Certification Services, LLC

SAR Value  ?  : Body-Worn Device/ Body-Supported Device (W/kg):
.61

Evaluated against exposure limits for devices used by the general public (uncontrolled environment)


Model:  Rad-87
Spec. Iss. From
Freq.
To
Freq.
Emission
Designation
Min.
Power
Max.
Power
Field
Strength
Dis.
(m)
RSS210 7.0 2.412 G 2.462 G 46M2G7W 30 mW
RSS210 7.0 5.18 G 5.24 G 16M5G7W 10 mW
RSS210 7.0 5.746 G 5.804 G 16M5G7W 10 mW
Note:
The above model table is generated based on information received from Certification Bodies, Manufacturers or Suppliers at time of certification.

Approval Agent:Mr. Steve Behm
Certified On:2008-01-11
Certified By:
CKC Certification Services, LLC
Wireless Lab:CKC LABORATORIES INC. (BREA)
3172A
Wireless Test Site:3172A-D
Spicific Absorbsion Test Lab:--
SAR Test Results:|Body:0.61 W/kg|

Frequency and Wireless Emission Stats

Rule SpecificaitonIssue No.Frequency RangeEmission DesignatorPower RangeField StrengthDistance
RSS210 7 5746.0 MHz - 5804.0 MHz G7W-- up to -- -- --
RSS210 7 5180.0 MHz - 5240.0 MHz G7W-- up to -- -- --
RSS210 7 5746.0 MHz - 5804.0 MHz G7W-- up to -- -- --
RSS210 7 5180.0 MHz - 5240.0 MHz G7W-- up to -- -- --
RSS210 7 5746.0 MHz - 5804.0 MHz 16M5G7W-- up to -- -- --
RSS210 7 5180.0 MHz - 5240.0 MHz 16M5G7W-- up to -- -- --

An IC ID is the product ID assigned by Industry Canada to identify wireless products in the Canadian market. IC typically assigns businesses 3 to 5 character codes to identify the business that created the product. For example, the business code for IC 7362A-RAD87 is 7362A. This particular IC Certification was filed for by MASIMO CORP. for implementation in their product model # Pulse Oximeter. Under "Similar Applications" below, you will find the other application and models this Industry Canada Certification ID has been filed with.

Approved Models for this IC ID:

Application ID IC ID Date Model
121549 7362A-RAD87 2007-10-29 Rad-87
122686 7362A-RAD87 2008-01-11 Rad-87

Related FCC ID Filings
FCC ID : Device
VKF-RAD87: Pulse CO-Oximeter
2007-10-26 - Masimo Corporation
VKF-RAD87: Pulse CO-Oximeter
2008-01-08 - Masimo Corporation
VKF-RAD87: Pulse CO-Oximeter
2007-10-26 - Masimo Corporation
VKF-RAD87: Pulse CO-Oximeter
2008-01-08 - Masimo Corporation